Влизам | регистрирам
Новини
Новини

Център за новини

първа страница > Център за новини > Блог
  • Detailed Explanation of the Basic Working Principle of a Vacuum Circuit Breaker

    Detailed Explanation of the Basic Working Principle of a Vacuum Circuit Breaker

    2025-12-15 09:37:24
    A vacuum circuit breaker uses a vacuum environment to achieve circuit interruption and protection. Inside the breaker, current flows through designated electrodes, generating a strong current composed of vapor and gas. When the switching operation occurs, the vacuum between the electrodes causes the...
  • When Should You Inspect Switchgear Fittings for Wear and Tear?

    When Should You Inspect Switchgear Fittings for Wear and Tear?

    2025-12-13 07:55:01
      When Should You Inspect Switchgear Fittings for Wear and Tear? Industry Background and Market Demand Switchgear is a critical component in electrical power distribution, ensuring safe operation by isolating faults and protecting equipment. As industries increasingly rely on uninterrupted p...
  • How to Future-Proof Your Switchgear with Upgraded Vacuum Circuit Breakers?

    How to Future-Proof Your Switchgear with Upgraded Vacuum Circuit Breakers?

    2025-12-12 07:53:24
      How to Future-Proof Your Switchgear with Upgraded Vacuum Circuit Breakers? Industry Background and Market Demand The global demand for reliable and efficient power distribution continues to grow, driven by industrial expansion, renewable energy integration, and aging electrical infrastruct...
  • Why Do High Voltage Electrical Equipment Failures Often Involve Switchgear Issues?

    Why Do High Voltage Electrical Equipment Failures Often Involve Switchgear Issues?

    2025-12-11 07:49:51
      Why Do High Voltage Electrical Equipment Failures Often Involve Switchgear Issues? Industry Background and Market Demand High voltage electrical systems form the backbone of modern power distribution, serving industries ranging from utilities to manufacturing plants. The reliability of the...
  • Exploring the Causes of Excessive Guide Rail Temperature and Corresponding Countermeasures

    Exploring the Causes of Excessive Guide Rail Temperature and Corresponding Countermeasures

    2025-12-08 10:04:07
    Excessive guide rail temperature may stem from multiple factors, such as insufficient lubrication or degraded lubricants, which increase friction and consequently raise the temperature. In addition, operating the guide rail under loads that exceed its designed capacity is also one of the common caus...
  • Impact of Poor Grounding on Electronic Controller Performance and Troubleshooting Methods

    Impact of Poor Grounding on Electronic Controller Performance and Troubleshooting Methods

    2025-12-04 10:13:32
    Poor grounding can cause instability in the operation of an electronic controller and may even lead to equipment failure. When the controller is not properly grounded, signal interference and incomplete current loops can easily occur, affecting its normal functionality. This situation may not only r...
  • Adjustment Methods for Resolving Asynchronous Operation of Disconnect Switches

    Adjustment Methods for Resolving Asynchronous Operation of Disconnect Switches

    2025-12-01 09:50:18
    In power systems, asynchronous opening and closing of disconnect switches may lead to abnormal equipment operation and affect system safety. First, the mechanical condition of the operating mechanism should be inspected to ensure proper lubrication and the absence of jamming. Next, verify that the c...
  • Repair Steps and Recommendations for Auxiliary Switch Poor Contact Issues

    Repair Steps and Recommendations for Auxiliary Switch Poor Contact Issues

    2025-11-28 09:27:00
    When dealing with poor contact problems in the auxiliary switch of a vacuum circuit breaker, the first step is to identify the cause of the fault. You can determine this by measuring the resistance of the auxiliary switch—if the resistance value is abnormal, it may indicate poor contact. Next, check...
  • Detection of Guide Rail Wear Conditions and Effective Repair Methods

    Detection of Guide Rail Wear Conditions and Effective Repair Methods

    2025-11-24 10:49:35
    Guide rail wear mainly includes issues such as surface scratches, dents, and material loss. To effectively detect these wear conditions, professional measuring tools such as hardness testers and micrometers can be used to evaluate the thickness and surface flatness of the guide rail. In addition, re...
  • Exploring the Important Functions of Electronic Controllers in Modern Equipment

    Exploring the Important Functions of Electronic Controllers in Modern Equipment

    2025-11-22 09:35:57
    Electronic controllers play a crucial role in modern equipment, serving primarily to achieve automatic control and management of various systems. By continuously monitoring real-time sensor data, the controller is able to analyze the operating status of the equipment and make adjustments according t...
  • Analysis of Contact Welding Issues and Reliable Solutions

    Analysis of Contact Welding Issues and Reliable Solutions

    2025-11-21 10:52:51
    Grounding switches play a critical role in power systems, but contact welding problems often lead to equipment failures and compromise system safety. Welding typically occurs during frequent switching operations or when the current exceeds the rated value, causing a sustained short circuit between c...
  • Potential Causes of High-Voltage Switchgear Tripping and Countermeasures

    Potential Causes of High-Voltage Switchgear Tripping and Countermeasures

    2025-11-19 10:50:48
    High-voltage switchgear tripping is usually associated with multiple factors. First, internal short-circuit faults are a common cause, which may result from insulation failure, equipment aging, or external interference. In such cases, it is recommended to conduct regular insulation tests to detect p...
  • Analysis of the Causes of Insulator Flashover Accidents and Their Countermeasures

    Analysis of the Causes of Insulator Flashover Accidents and Their Countermeasures

    2025-11-18 10:05:19
    Insulator flashover accidents typically occur during rainy weather or in humid environments, mainly due to electrical breakdown caused by surface contamination and moisture on the insulator. First, contamination layers reduce the insulating capability of the insulator surface, making it easier for c...
  • Methods to Prevent Insulated Pull Rod Fracture in Vacuum Circuit Breakers

    Methods to Prevent Insulated Pull Rod Fracture in Vacuum Circuit Breakers

    2025-11-17 11:20:02
    To effectively prevent the insulated pull rod of a vacuum circuit breaker from breaking, regular inspection and maintenance are essential. During inspections, pay close attention to the insulation material of the pull rod and check for signs of wear, aging, or degradation. Maintaining appropriate en...
  • Фактори, причиняващи блокиране на направляващи релси и решения

    Фактори, причиняващи блокиране на направляващи релси и решения

    2025-11-15 09:27:49
    Има множество често срещани фактори, които водят до блокиране по време на работа на водещите релси. Първо, недостатъчното смазване е основната причина за повишено триене. Редовното добавяне или подмяна на смазочно масло може значително да подобри експлоатационното състояние на водещата релса. В допъ...
  • Боравене с окисляване на релейни контакти в електронен контролер

    Боравене с окисляване на релейни контакти в електронен контролер

    2025-11-14 09:28:25
    Окисляването на контактите на релето е често срещан проблем при използването на електронни контролери и неправилното боравене може да повлияе на работата на устройството. Първо, редовно проверявайте контактите на релето за признаци на окисление. Ако се открие оксиден слой, той трябва да се почисти н...
  • Често срещани причини за неизправност при работа и противодействие за заземителни превключватели

    Често срещани причини за неизправност при работа и противодействие за заземителни превключватели

    2025-11-13 09:37:23
    Неизправностите при работа на заземителните превключватели обикновено произтичат от няколко ключови фактора. Първо, механичните повреди са една от основните причини, като износване или повреда на задвижващия механизъм, което може да попречи на превключвателя да работи правилно. Второ, електрическите...
  • Стъпки за отстраняване на неизправности, които трябва да знаете за повреда на прекъсвача

    Стъпки за отстраняване на неизправности, които трябва да знаете за повреда на прекъсвача

    2025-11-12 13:45:15
    Когато работите с прекъсвач, който не се задейства, първата стъпка е да проверите управляващото напрежение на прекъсвача. Уверете се, че управляващото захранване функционира правилно и че напрежението е в определения диапазон. В същото време проверете дали клемите на разпределителната уредба не са р...
общо 51 Лента, Всяка страница показва:18 Лента
Свържете се с нас

Телефон: +8613736779975

Имейл: sales@vcbbreaker.com

Води: 66 Road, Iconient Economic Development Development Zone, Zheji, Китай

Copyright ©  2025 Eberry Electric Group  Всички права запазени

Карта на сайта

Този уебсайт използва бисквитки, за да гарантира, че получавате най-доброто изживяване на нашия уебсайт.

Приеми отхвърлям