Влизам | регистрирам
About Us
първа страница > Етикет > 3-12kV AC заземителен превключвател

3-12kV AC заземителен превключвател

Of course. Here is a 500-word description of a 3-12kV AC Earthing Switch.An AC Earthing Switch is a fundamental safety device installed in medium-voltage (MV) switchgear, specifically within the 3kV to 12kV range. Its primary and critical function is to ensure the safe isolation of a circuit section for maintenance, repair, or inspection by providing a visible and reliable earth (ground) connection. It is a manually or motor-operated mechanism, never intended for interrupting load or fault current but solely for securing a de-energized state.The core purpose of the earthing switch is personnel and equipment protection. After a circuit breaker has opened to isolate a section, residual capacitive charges can remain on the cables and equipment. Furthermore, accidental re-energization from the upstream side poses a lethal risk. The earthing switch mitigates these dangers by physically connecting the isolated busbars or cables directly to the earth potential. This action safely discharges any residual energy and creates a short-circuit path. Should an accidental energization occur, it would immediately trigger the upstream protective devices (circuit breakers, fuses), thereby preventing injury to personnel working downstream.Key components of a typical 3-12kV earthing switch include: Main Contacts: Often made of robust, corrosion-resistant materials like copper or copper alloys, designed to reliably carry high short-circuit currents for a specified duration (e.g., 3 seconds, 25kA). Operating Mechanism: A manual operating handle or a motor-driven actuator. The mechanism is frequently interlocked to prevent unsafe operation. Insulation System: The live parts are mounted on insulating supports (e.g., epoxy resin insulators) to maintain integrity against the system voltage. Interlocking Systems: This is arguably its most crucial safety feature. Mechanical and/or electrical interlocks prevent the earthing switch from being closed when the associated circuit breaker is closed or the isolating disconnector is in the "ON" position. Conversely, they prevent the circuit breaker from being closed while the earthing switch is engaged.Earthing switches are classified into two main types based on their application within the switchgear panel:1. Busbar Earthing Switch: Used to earth the main busbars.2. Cable Earthing Switch: Used to earth the outgoing cable feeder after the circuit breaker.These devices are rigorously designed and tested in accordance with international standards such as IEC 62271-102. They must withstand dynamic and thermal stresses under short-circuit conditions, demonstrate adequate mechanical endurance (number of operating cycles), and function reliably across a wide ambient temperature range.In summary, within the 3-12kV electrical distribution landscape, the AC Earthing Switch is an indispensable guardian of safety. It is the final, verified step in creating a secure working environment, ensuring that electrical circuits are not just de-energized but are positively and visibly grounded before any human intervention.

продукт

Класификация:
Метод на показване:

Новини

Класификация:
Все още няма резултати от търсенето!

случаят

Класификация:
Все още няма резултати от търсенето!

видео

Класификация:
Все още няма резултати от търсенето!

Изтегли

Класификация:
Все още няма резултати от търсенето!

подбор на персонал

Класификация:
Все още няма резултати от търсенето!

Препоръчани продукти

Contact Us

Phone: +8613736779975

E-mail: sales@vcbbreaker.com

Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China

Copyright ©  2025 Yangmei Electric Group  Всички права запазени

Карта на сайта

Този уебсайт използва бисквитки, за да гарантира, че получавате най-доброто изживяване на нашия уебсайт.

Приеми отхвърлям